FMH (Frame Mount Horizontal)

REVERSE OSMOSIS SYSTEM
Model: FMH (Frame Mount Horizontal)
12,000 to 41,400+ GPD

STANDARD FEATURES

  • Reverse Osmosis Membrane
  • Powder-coated steel frame
  • Stainless steel multi-stage pump
  • 80″ membrane vessel
  • SCH 80 PVC manifolding
  • Feed/concentrate pressure gauges
  • Liquid-tight wire shrouding
  • Motorized inlet ball valve
  • Adjstbl. s.s. concentrate valve
  • Product/Concentrate/Recycle sensor powered flow meters
  • product sampling valves per vessel
  • Two 20″ 5 micron pre-filters
  • Pre and post-filter gauges
  • Victaulic couplings
  • Stainless steel throttling switch
  • Fused main disconnect switch
  • Low voltage dual-level product switches
  • Optimum performance membrane array

STANDARD ELECTRICAL CONTROLS:

    • Menu system with Keypad
    • Product and Feed water TDS monitoring
    • Manual start override on tank full condition
    • Feed water temperature
    • Low voltage level control
    • Hour Meter
    • Audible low pressure alarm
    • Low pressure switch
    • System ON/OFF
    • Time delay start
    • Low pressure bypass delay

OPTIONS:

  • Nanofiltration Membrane
  • Automatic flush
  • Pre-treatment lock-out
  • Permeate purge
  • Antiscalant pump w/tank
  • Hi-pressure cut-off
  • Product diversion
  • Stainless Steel multiple cartridge filter housing to be used for sediment removal 
  • 3phase motor w/IEC motor contactor
  • 50hz electrical

 

MODEL GPD MEMBRANE
4″X40″ QTY
OPERATING
PRESSURE
FMH4-2
FMH4-2S
12,000+
13,800+
8
8
200psi
150psi
FMH6-2
FMH6-2S
18,000+
20,700+
12
12
200psi
150psi
FMH8-2
FMH8-2S
23,700+
27,600+
16
16
200psi
150psi
FMH10-2
FMH10-2S
29,900+
34,500+
20
20
200psi
150psi
FMH12-2
FMH12-2S
35,000+
41,400+
24
24
200psi
150psi

FEED WATER PARAMETERS:

  • Temperature: 85° F maximum
  • Pressure: 40 – 80 psi maximum
  • TDS: 2000-5000 ppm maximum (Consult Dealer for specific model)
  • Iron tolerance: 0.5 ppm maximum
  • Hydrogen sulfide: must be removed
  • Silica tolerance: can not be higher than 100 ppm in the concentrate stream.
    (Antiscalant should be considered for any levels over 75 ppm)
  • Turbidity: should be removed
  • Hardness: must be removed


OPERATING PARAMETERS:

  • Operating pressure: 150 – 200 psi maximum
  • Water recovery: up to 70% and is field adjusted by customer.
    (It is not recommended that the recovery be set higher than 70%)
  • pH range: 3 – 11
  • Flow rates are determined by the membrane mfg.’s. testing criteria of 1500 ppm Nacl solution, 77°F water temperature, 225 psi at 10-15% recovery. Typical membrane salt rejection is 95-99%

*Actual flow rates may vary depending on the pre-treatment used, water conditions, feed water temperature and applied pressure, etc.